OEM fans and industrial process high pressure radial blowers and ventilators. Engineering sales of centrifugal backwardly curved ventialators and airfoil fan blowers.
radial blowers

Industrial radial blower

RBO, RD, BP, LS, XO, DH, RTS, Radial Tip Blowers: industrial radial blade blowers are supplied in welded heavy gauge steel construction to prevent flexing at high pressure. Available in direct drive arrangements 4 / 4V / 4H / 7 / 8 and fan belt drive arrangements 1/3/9/10. Arr. 10 blowers are known as ventilating sets (fan vent sets). Available in single width single inlet (SWSI), or double width double inlet (DWDI) blower designs. Capacities: to 500,000 CFM. Static pressure up to 100 inches water gauge depending on the class of construction. Typical fan class of construction is Class 1, 2, 3, 4, 5.

Aluminum wheel, Steel wheel, or FRP blower wheel: industrial radial blowers and fans are supplied with aluminum wheel or corten wheel to meet requirements of AMCA A, and AMCA B spark resistant fan construction. Mild steel blower wheels are of all welded construction. They are used on pressure applications, material handling fan applications (plastic scrap, paper trim, granular material, low density bulk material) where wheel is reinforced with support gussets, or made of abraision resistant construction, or furnished of high strenght steel. Stainless steel ventilator wheel in 304 SS, 316 SS, 316 SS, 2205 SS are supplied for corrosive applications, or high tempearature applications. The blower pressure curve remains stable from fully open to fully closed position.

Inlet flanges, outlet flanges, companion flanges: continuosly welded to match ANSI class 125/150, DIN, ISO, or custom hole pattern.

Shaft seal and low leakage blower construction: shafting is straightened to close tolerance to minimize "run-out" and ensure smooth operation. Teflon fan shaft seal, ceramic shaft seal and lubricated shaft seals (Buna, Teflon, Viton) are standard. Red silicone gasketing is provided for low leakage construction and for high temperature construction. Heavy-duty spherical roller ventilator bearings are standard.

Heat fan construction up to 1500 F: includes high temperature paint (up to 1000 F), special alloy construction, shaft cooler, shaft-cooler guard, and steel wheel, or alloy wheel, with steel, or alloy housing.

Cladding for sound attenuation and silencers: cladding consists of 2 inches mineral-wool insulation covered with a welded steel jacket. As an inexpensive alternative is offered slide-on acoustic cloth jackets. Inlet silencer/outlet silencer are supplied with matching flanges for further attenuation of the noise level.

Inlet filter assemblies: cell type, 1 inch, or 2 inch filters are available with filter cabinet to be mounted at fan inlet. Bird guard, insect screen and weather hood are optional accessories with inlet filter package.

Standard accessories:flash / raised access door, inspection port, drain and plug, unitary base, shaft and bearing guard, belt guard, motor cover, spring vibration isolation, rubber-in-share (RIS) vibration isolation, vibrating pads, outlet damper, inlet vane damper, external inlet vane damper, evase, electrical / pneumatic actuators.








Industrial ventilators and fans, process pressure blowers, regenerative pressure blowers; industrial; process and commercial heating; ventilating and air-conditioning equipment. Suppliers of cool air blowers, high volume air ventilators, air blower motors, pneumatic blowers, compressed air blowers, suction pressure blowers, air blower compressores, high pressure axial fans, propeller fans, axial prop fans, industrial fan motors, big industrial fans, large industrial ventilators, industrial blower systems, explosion proof ventilation fans, rooftop fans and ventilators, shop fans, building ventilation fans.
Roof and wall exhaust and supply power ventilation fans for industrial and commercial HVAC. Sales of axial propeller fans; inline blowers; centrifugal fan ventilators; square in-line fans; FRP fan blowers; wall and roof exhauster fans

The containment of volumes of contaminated air, odors or other emissions can require specialized fan equipment. Industrial ventilation practice dictates that capture of these process materials is usually best accomplished at the source. The design of the hoods and systems necessary for these source capture tasks is a specialized skill. Usually these emissions are conveyed to a filtration or destruction device. Fans are located on the clean side of these filters, but occasionally design requirements call for material-handling or corrosion-resistant fans.

Canada Blower makes a wide variety of fans and blowers in many materials to accomplish this task. From the simplest exhaust hood with a fan, to a complex industrial oxidizer, Canada Blower can help with the necessary fans. When processes produce fumes, the exhaust system can simply remove the fumes from the occupied space. If the fumes are corrosive, the materials of construction for the fans and duct system must be protected. CBC makes fans in several alloys with special fan coatings available.

If the fumes are corrosive, the materials of construction for the fans and duct system must be protected. Canada Blower makes fans in several alloys with special coatings available.

Capture and control of emissions is accomplished by creating air movement. Every type of fan design can be used to move air through a filter or process scrubber. The fans / blowers can be installed on the clean side of the capture / destruction device which calls for high-efficiency, minimum power consumption designs. Dirty air fans for capture/destruction devices would require more rugged-duty industrial designs. These capture devices can be designed for continuous operation or shut down regularly for cleaning. Occasionally, the air is corrosive or contains gases that require special fan construction to resist wear.